A pipeline safety management system is voluntary. The thing it provides, programs that work as one system, is not optional at all. Most operators are further along than they think.
The industry has already identified the best way to help get us to zero, and it has moved a long way toward it. PHMSA’s March 2025 advisory bulletin recites that nearly 85 percent of pipeline mileage is covered by a pipeline safety management system. In the industry’s 2024 annual report, 88 percent of responding operators agreed or strongly agreed that their system was improving safety performance. That is a real record, built voluntarily.
There is still an understandable wariness about the phrase. It sounds like a new program to build, a new manual to maintain, and one more framework on top of the mandatory ones. An operator can look at that and reasonably decide it is not a priority right now. We are not going to argue anyone into a label.
But separate the label from the thing. The label is voluntary. The thing it describes, a set of programs that behave as one system instead of a stack of separate binders, is not something any operator opts out of. Every operator with more than one program document already has some degree of coherence between them, deliberate or accidental, managed or drifting. The only real choice is whether yours is on purpose.
You already own most of it
Federal regulation already requires roughly ten written programs: the O&M Manual, the Emergency Response Plan, corrosion control, the Integrity Management Program for transmission or distribution, the OQ Program, the Public Awareness Program, the Damage Prevention Program, control room management, drug and alcohol, and the records and reporting under all of it. On the gas side that is Part 192; on the liquid side, Part 195 carries the same set, with more of it gathered inside the manual section, 195.402.
Map those programs against the ten elements of API RP 1173, first edition, and eight of the ten elements already have required work behind them before anyone writes anything new:
- Risk management: the Integrity Management Program
- Operational controls: the O&M Manual and the programs it contains
- Emergency preparedness: the Emergency Response Plan
- Stakeholder engagement: the Public Awareness and Damage Prevention Programs
- Competence: the OQ Program
- Safety assurance: the periodic review of field work that both parts require, to judge whether the O&M procedures are effective (192.605(b)(8) and 195.402(c)(13))
- Documentation: the manual
- Incident investigation: required incident reporting and integrity feedback, though no single document owns it
Required work behind an element is not the same as a satisfied element. RP 1173 asks for more than the rules do in nearly every case. Competence is the clearest example: the OQ Program qualifies people on covered tasks, and the element also reaches training and awareness the OQ Rule was never written to touch. Read the count as a head start on eight of the ten, not as credit for eight finished elements.
Only two elements have nothing behind them: leadership and management commitment at the front of the cycle, and management review and continuous improvement at the back. No provision of Part 192 or Part 195 requires either one. They are also the two that turn a set of programs into a system.
What actually stands in the way
If eight of the ten already have required work behind them, why has adoption stalled at the smallest operators? PHMSA’s own bulletin says more than half of the smallest category describe their efforts as stalled.
Usually it is not missing documents. A document set is not a system. The programs can each be complete, current and defensible on their own terms and still not work together. The corrosion crew records a deficiency and the integrity engineer never sees it. The OQ Program lists a covered task the O&M Manual no longer describes. A change to the manual never reaches the training. Nothing in any of those sentences breaks a rule, and all of them are risk.
That property, whether the documents agree with each other and whether information moves between them, is what we call coherence. Conformance is whether each document is right. Coherence is whether they are right together. A management system built on an incoherent document set inherits the disconnection and formalizes it: you end up with a mature process for reviewing documents that disagree with each other.
Under a risk goal
Under a compliance goal, the voluntary label is easy to set aside, because no inspector will ask for it. Under a risk goal, the question is different: are our programs working as one system, and how would we know? That question applies to every operator, with or without the label, and it is the one a management system exists to answer.
The case for this mapping is made in full in The System You Already Have, the first paper in our white paper series, free on our Coherence page.
If you want to see how much of a system you already have, and where the parts do not yet agree, that is what an SC Diagnostic measures. Turning that picture into a deliberate, maintained management system is what our Management-System Work is for.
Compliance should be systemic.
API RP 1173 is a voluntary recommended practice. The mapping of program documents to its elements is Systemic Compliance’s analytical reading for planning purposes and should be confirmed against your own programs. Systemic Compliance is not a law firm.